Home

Product >> Rolling Stock Cable

Rolling Stock Cables

Multi Core

Ruber Type, Unscreened Cable   

Rubber Type 

Voltage

Cable Type

Construction

Number of Cores

Cross Sectional
Areas/Stranding Class

Design Standard

Fire Standard

300/500V

Multicore, with jacket

CU/EPR/PCP

1,2,3 Prs

1.0mm2-4.0mm2

N/A

N/A

600/1000V

Multipair, with jacket

CU/EPR/PCP

12-42C

1.0mm2-4.0mm 2

N/A

N/A

LSOH Type 

Voltage

Cable Type

Construction

Numberof Cores

Cross Sectional
Areas/Stranding Class

Design Standard

Fire Standard

300/500V

Multicore,with jacket

CU/EI 110 EPR/EM 104 EVA

1-21C

0.75mm2 - 6mm2, Class 5 Stranding

EN 50264-3-2

EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4

600/1000V

Multicore,with jacket

CU/EI 110 EPR/EM 104 EVA

1-21C

0.75mm2 - 6mm2, Class 5 Stranding

EN 50264-3-2

EN 50267-2-1/2, EN50305,EN 50305, EN 50268-2, BS6853, DIN 5510 P1,HAZARD LEVEL 1-4

600/1000V

Multicore,with jacket fire resistant

CU/MICA/EI107 EVA

1-21C

0.75mm2- 6mm2,Class 5 Stranding

EN 50264-3-1

EN 50267-2-1/2, EN50305,EN 50305, EN 50268-2,BS6853, DIN 5510 P1,HAZARD LEVEL 1-4,EN 50200 (15MIN)

1800/3000V

Multicore,with jacket

CU/EI 110 EPR/EM 104 EVA

2-37 C

1.5mm2-2.5mm2,Class 5 Stranding

EN 50264-3-1

BS 6853A/B/II,NF F 16 101

 Rubber Type

300/500V Multipairs rubber cable with jacket

Cross-sectional

0.75mm2-1mm2

Voltage rating

300-500V

Number of Pairs

1-3

Conductor class

IEC 60228 Class 5

Insulation

EPR

Jacket

PCP


No. of Cores/Pairs

Cross Sectional Area(mm²)

Number and Nominal Diameter of Strands(mm)

Voltage Rating(V)

Nominal Overall
Diameter (mm)

Nominal Weight (kg/km)

1 Pair

0.75

24/0.2

300/500

10.0

160.0

1 Pair

1.0

32/0.2

300/500

10.7

180.0

1 Pair

1.0

32/0.2

300/500

12.5

230.0

2 Pair

1.0

32/0.2

300/500

22.0

590.0

3 Pair

1.0

32/0.2

300/500

22.4

630.0

1 Pair

1.0

32/0.2

300/500

15.7

290.0

300/500V Multicore rubber cable with jacket

Cross-sectional

1.0mm2-4.0mm2

Voltage rating

300-500V

Number of Cores

12-42

Conductor class

IEC 60228 Class 5

Insulation

EPR

Jacket

PCP


No. of Cores/Pairs

Cross Sectional Area(mm²)

Number and Nominal Diameter of Strands(mm)

Voltage Rating(V)

Nominal Overall
Diameter (mm)

Nominal Weight (kg/km)

12 Core

1.0

32/0.25

300/500

20.3

450.0

19 Core

2.5

50/0.25

300/500

26.4

1200.0

27 Core

2.5

50/0.25

300/500

32.0

1500.0

36 Core

1.5

30/0.25

300/500

34.6

1600.0

42 Core

1.5

30/0.25

300/500

38.4

1900.0

10 Core

2.5

50/0.25

300/500

28.1

910.0

20 Core

4.0

56/0.3

300/500

42.7

2400.0